welcome!

All Hazmat Models are FM approved and are EPA & OSHA compliant. Electrical installed in accordance with the NEC 2014 edition and include UL Classified electrical accessories. Electrical Classification available at an additional charge.

Hurricane Rated & Tornado Resistant Walls

2 or 4 Hour Fire Rated wall construction

featured

Chemical Storage Buildings

Securall Buildings
Standard Feature: Agri Chemical Storage Building.

Securall® Chemical Storage Buildings are designed with a wide variety of standard features to help our customers gain compliance with hazmat storage codes quickly and easily. Pesticide Storage Buildings are designed for storage of hazardous agricultural and turf-management chemicals.

Securall®'s quality cannot be beat with standard features such as corrosion-resistant, galvannealed steel construction, tornado and hurricane resistant walls, and interlocking wall panels designed for superior strength and durability.

All models are FM approved and are EPA and OSHA compliant. Electrical installed in accordance with the NEC 2014 edition and include UL Classified electrical accessories. Electrical Classification available at an additional charge.


Design Features

R-11 Fiberglass insulation in ceiling and walls

Commercial grade lockset

Moisture Resistant Exterior Light with Photocell

GFCI Duplex receptacle with weatherproof cover

Steel shelving (3 Tiers) with raised edges

Chemical, corrosive, ultraviolet and impact resistant paint

Leak-tight continuously welded sump

Heavy gauge aluminum threshold

 

Warning labels

Safety posters

Dust Proof/Fluorescent Interior Light with Weatherproof Switch

Forklift channels with anchoring brackets

Natural convection air vents

Removable Galvanized Steel Safety Flooring

Reflective warning tape marking entryway

Hurricane Resistant Walls

Securall Buildings
Agri Chemical Buildings Standard Feature: Hurricane Resistant Walls.

Securall® Buildings have been tested to determine the amount of force they can withstand and were shown to withstand F-4 tornado force winds of 250 mph. The chart demonstrates the wind speed that a particular length of wall will resist.
Upgrade package is available for Tornado Resistant Walls.



Interlocking Wall Sections

Securall Buildings
Agri Chemical Buildings Standard Feature: Interlocking Wall Sections.

Securall® Chemical Storage Buildings are designed using which provide superior strength and durability.



Exterior Wall Construction

Securall® AG Buildings are all-welded using 12 or 16 gauge galvannealed steel outer walls and 20 gauge cold rolled steel inner walls provide maximum durability, weather resistance, and rigidity.


Fire Rating - FM Approved Fire Rated Wall & Roof Design Tested at Intertek Testing Laboratory

Securall Buildings
FM Approved Fire Rated Wall & Roof Design Tested at Intertek Testing Laboratory

Securall® Fire-Rated Storage Buildings (8'4"H X 42'W X 9'D Max Dimensions) carry the Factory Mutual System Approval label and have an FM Approved Fire Rated Wall & Roof Design. Wall and Roof are Tested at Intertek Testing Laboratories. Securall® Fire-Rated Storage Buildings constructed based upon UL Fire Resistance Ratings classification criteria. Standard models are available in 2-hour and 4-hour fire ratings. Wall ratings are either 2 or 4 hour fire rated . Roof ratings are either 1.5 or 3 hour fire rated (Check with your local authority having jurisdiction for correct wall/roof rating needed). In addition, all Fire-Rated Buildings come with hydraulic operated self-closing, fire-rated doors and fire damper protected vents.

2 Hour Fire Rated wall construction built with 1.5 hour fire rated roof construction, 1.5 hour fire rated door construction, and 2 hr wall design. Air inlet vents with UL Classified and labeled fire damper with louvers. Dampers have a galvanized steel frame, curtain-type galvanized steel blades and a UL Classified 165° F fusible link.

4 Hour Fire Rated wall construction built with 3 hour fire rated roof construction, 3 hour fire rated door construction, and 4 hr wall design. Air inlet vents with UL Classified and labeled fire damper with louvers. Dampers have a galvanized steel frame, curtain-type galvanized steel blades and a UL Classified 165° F fusible link.

Please check with your local authority having jurisdiction for setback requirements and correct wall/roof rating needed.


Safety Floor Planking

Securall Buildings
Agri Chemical Buildings Standard Feature: Slip resistant planking.

Slip resistant planking 9" wide, 12 gauge galvanized steel with raised perforated buttons and debossed holes protruding down. Galvanized steel floor planking above sump area for maximum corrosion resistance. Floor planking designed to sustain a minimum uniformly distributed load of 250 pounds per square foot. Floor planking and supports are removable to facilitate sump cleaning in the event of a spill.


Door Style

Door for AG200-AG400 Provide one (42" wide x 62.5”) and AG600-AG1200 Provide one (42” wide x 80”) high door to facilitate the unloading and loading of hazardous material within the building. Installed with a UL Classified commercial grade keyed lockset. The door shall serve as personnel entrance and exit.

Door for AG1600-AG8000 Provide one 60” wide x 80” high double door to facilitate the unloading and loading of hazardous material within the building. Installed with a UL Classified commercial grade keyed lockset. The double door shall have one active leaf to serve as personnel entrance and exit. The active leaf must be equipped with a door closer available on AG600-B1200 fire rated models.


Explosion Relief Panels

Used in the construction of buildings designed for the storage and dispensing of Class IA and Class IB flammable liquids. Explosion relief panels limit the damage within an enclosed hazardous location. When the panel(s) are subjected to an explosive force, the pressure relieving panel quickly vents the force before it causes major damage. The panels are designed to release at 20 psf.

need more information?
Securall Securall Securall Securall